$3954
Input voltageUL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 12
Input voltageUL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominalEV connector (EVC-13)SAE J1772 socket, 16 A (type 1, 5P single-phase)Internal power consumption2 W max.Operating temperature-4 °F to 104 °F (-20 °C to 40 °C)Storage temperature-4 °F to 122 °F (-20 °C to 50 °C)Operating humidity range10 % to 85 % relative humidity non-condensingStorage relative humidity0 % to 85 % non-condensingOperating altitude6561 ft (2000 m) max.Dimensions (H × W × D)Approx. 8.66 x 4.33 x 1.77 in (220 x 110 × 45 mm) without cable assemblyWeightApprox. 4.4 lb (2 kg)Safety standardsIEC 61010-1, Pollution Degree 2
IEC 61010-2-030Measurement categoryCAT II 250 VIP protection classIP54Electromagnetic Compatibility (EMC)InternationalIEC 61326-1: Basic Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.FunctionsCP StatesA, B, C, DCP Error “E”On/offPE ErrorOn/offGFCI TestYes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 msPE Pre-Test (typical)Visible indication >30 V on PE conductorOutputs (for test purpose only)Measuring terminals
L1, L2/N, PEMax. 250 V 50/60 Hz, CAT II 250 VCP signal output terminalsApprox. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE Frequency response - dc coupledWithout probes and test leads (with BB120)123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)Frequency response - ac coupled (lf roll off)Without probes and test leads100 dB @ dc, >60 dB @ 50, 60, or 400 HzFull scale reading5000 countsRanges500 mV, 5 V, 50 V, 500 V, 750 VAccuracy for 5% to 100% of range (DC coupled)DC to 60 Hz (V ac+dc)±(1% +10 counts)±(1% +10 counts)Accuracy for 5% to 100% of range (AC or dc coupled)60 Hz to 20 kHz±(2.5% +15 counts)DC rejection (only VAC)>50 dBCommon mode rejection (CMRR)>100 dB @ dcFull scale reading5000 counts, reading is independent of any signal crest factor.ModesMax peak, Min peak, or pk-to-pkRanges500 mV, 5 V, 50 V, 500 V, 2200 VAccuracyAccuracy Max peak or Min peak5% of full scale10% of full scaleFull scale reading500 countsRanges123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHzFrequency range15 Hz (1 Hz) to 50 MHz in continuous autosetAccuracy @1 Hz to 1 MHz±(0.5% +2 counts)Full scale reading10,000 countsMax reading50.00 kRPMAccuracy±(0.5% +2 counts)Range2% to 98%Frequency range15 Hz (1 Hz) to 30 MHz in continuous autosetFrequency range15 Hz (1 Hz) to 30 MHz in continuous autosetFull scale reading1000 countsWith current clampRangesSame as V dc, V ac, V ac+dc, or PEAK0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mASame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)Range200 °C/div (200 °F/div)Scale factor1 mV/°C and 1 mV/°FAccuracyAs V dc (add temp. probe uncertainty)0 dBV1 V0 dBm (600 Ω /50 Ω)1 mW referenced to 600 Ω or 50 ΩdB onV dc, V ac, or Vac+dcFull scale reading1000 countsRange1 to 10Full scale reading90 CountsModesA to B, B to ARange0 to 359 degreesResolution1 degreeConfigurations1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)Power factor (PF)Ratio between watts and VA range - 0.00 to 1.00WattRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)999 countsVAVrms x Arms999 countsVA reactive (var)√((VA)2-W2)999 countsPurposeTo measure on pulse width modulated signals, like motor drive inverter outputsPrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequencyAccuracyAs Vrms for sinewave signals Input A to commonRanges123B and 124B500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩAccuracy±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)Full scale reading50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 countsMeasurement current0.5 mA to 50 nA, decreases with increasing rangesOpen circuit voltage2.8 V 10 HzWarrantyLifetimeBattery LifeAlkaline~400 hours typical, without backlightShock1 Meter drop per IEC 61010–1:2001VibrationPer MIL–PRF–28800 for a Class 2 instrument